Thecnc2020 | Explanation of machine data and setting data Siemens Parameter Manual |
Explanation of machine data and setting data Siemens Parameter Manual | Thecnc2020 |
Explanation of machine data and setting data
The machine data and the setting data are listed in form of tables shown below:
Expanded table
The expanded table includes data from the standard table plus additional rows with system-
specific values.
A dash "-" in a field means that the same value as for <System 1> applies for the specified
system.
The entry "-/-" in the "Protection" field means that the machine data is not available for the
specified system.
Example:
MD number and identifier
MD and SD are addressed via their numbers or their names (identifiers). The number and the
name, as well as the activation type and the unit are displayed on the screen of the control
system.
In the field "identifier", you can see the name of the data.
1.1 Data in the list
Cross reference
Attributes
For a detailed description of the appropriate data, refer to the description of functions or
manual/guide specified.
The "Attributes" field contains additional attributes of the data:
Unit/unit system
Depending on MD10240 SCALING_SYSTEM_IS_METRIC, the physical units of the machine
data (MD) differ as follows:
Dimension
The "Dimension" field contains the number of elements of a data field.
Activation
Display filter
The control system has defined four activating conditions. Each machine has a corresponding
activating condition:
• PO: Power On (activate by powering on)
• RE: Reset (activate by pressing RESET key)
• CF: Config (activate by pressing vertical softkey "Activate")
• IM: Immediate (activate immediately after your change)
The "Display filter" field contains the identifier of the data filter setting that enables the data to be seen. Using the filter setting, the exact data areas required at a given time can be selected for display.
Comments